The ECB-bus was defined in 1984 by the german company KONTRON.
It was defined for the 100x160mm-europa-card and used 2x32 pins of a
3x32-pin-connector (row a and c).
Later the third (middle) row of pins was defined for additional signals
used in 16-bit-systems. This extended bus uses all 3x32pins.
Pin | Name | Desciption |
a1 + | 5V + | 5 volts dc |
a2 D | 5 D | ata line bit 5 |
a3 | D6 | Data line bit 6 |
a4 | D3 | Data line bit 3 |
a5 | D4 | Data line bit 4 |
a6 | A2 | Address 2 |
a7 | A4 | Address 4 |
a8 | A5 | Address 5 |
a9 | A6 | Address 6 |
a10 | WAIT/ | CPU wait |
a11 | BUSRQ/ | bus request |
a12 | ||
a13 | ||
a14 | ||
a15 | ||
a16 | ||
a17 | ||
a18 | A14 | address 14 |
a19 | ||
a20 | M1/ | first cycle |
a21 | ||
a22 | ||
a23 | ||
a24 | ||
a25 | ||
a26 | ||
a27 | IORQ/ | in/out request |
a28 | RFSH/ | refresh cycle |
a29 | A13 | address 13 |
a30 | A9 | address 9 |
a31 | BUSAK/ | bus acknowledge |
a32 | GND | signal ground |
Pin | Name | Desciption |
c1 | +5V | +5 volts dc |
c2 | D0 | Data line bit 0 |
c3 | D7 | Data line bit 7 |
c4 | D2 | Data line bit 2 |
c5 | A0 | Address 0 |
c6 | A3 | Address 3 |
c7 | A1 | Address 1 |
c8 | A8 | Address 8 |
c9 | A7 | Address 7 |
c10 | ||
c11 | IEI | interrupt enable in |
c12 | ||
c13 | ||
c14 | D1 | Data line bit 1 |
c15 | ||
c16 | IEO | interrupt enable out |
c17 | A11 | address 11 |
c18 | A10 | address 10 |
c19 | ||
c20 | NMI/ | not maskable interrupt |
c21 | INT/ | normal interrupt |
c22 | WR/ | write cycle |
c23 | ||
c24 | RD/ | read cycle |
c25 | HALT/ | cpu stopped |
c26 | ||
c27 | A12 | address 12 |
c28 | A15 | address 15 |
c29 | ||
c30 | MREQ/ | memory request |
c31 | RESET/ | cpu reset |
c32 | GND | signal ground |
Pin | Name | Desciption |
b1 | +5V | +5 volts dc |
b2 | A20 | address 20 |
b3 | A21 | address 21 |
b4 | A22 | address 22 |
b5 | A23 | address 23 |
b6 | D8 | data line bit 8 |
b7 | D9 | data line bit 9 |
b8 | D10 | data line bit 10 |
b9 | D11 | data line bit 11 |
b10 | D12 | data line bit 12 |
b11 | D13 | data line bit 13 |
b12 | D14 | data line bit 14 |
b13 | D15 | data line bit 15 |
b14 | IRQ7 | interrupt 7 |
b15 | IRQ6 | interrupt 6 |
b16 | IRQ5 | interrupt 5 |
b17 | IRQ4 | interrupt 4 |
b18 | IRQ3 | interrupt 3 |
b19 | IRQ2 | interrupt 2 |
b20 | IRQ1 | interrupt 1 |
b21 | IRQ0 | interrupt 0 |
b22 | IOWR | I/O write |
b23 | ?? | ?? |
b24 | IORC | I/O read |
b25 | MRDC | Mem read |
b26 | ?? | ?? |
b27 | MWRC | Mem write |
b28 | DS0 | Data Select 0 |
b29 | DS1 | Data Select 1 |
b30 | OFF | bus driver tristate |
b31 | LOCK | bus driver tristate disabled |
b32 | GND | signal ground |
DS0 | DS1 | Description |
---|---|---|
0 | 0 | data transfer 16-bit |
0 | 1 | only bit 0-7 |
1 | 0 | only bit 8-15 |
1 | 1 | no data transfer |
Note: / = Active Low