Special invention by IBM for use on IBM RS/6000 and IBM PS/2
(at ???)
60 PIN BURNDY (C-60) at ???
Pin | Name | Dir | Description |
---|---|---|---|
1 | GND | Ground | |
2 | DB0 | Data Bus 0 | |
3 | GND | Ground | |
4 | DB1 | Data Bus 1 | |
5 | GND | Ground | |
6 | DB2 | Data Bus 2 | |
7 | GND | Ground | |
8 | DB3 | Data Bus 3 | |
9 | GND | Ground | |
10 | DB4 | Data Bus 4 | |
11 | GND | Ground | |
12 | DB5 | Data Bus 5 | |
13 | GND | Ground | |
14 | DB6 | Data Bus 6 | |
15 | GND | Ground | |
16 | DB7 | Data Bus 7 | |
17 | GND | Ground | |
18 | DPB | Data Parity (odd Parity) | |
19 | GND | Ground | |
20 | GND | Ground | |
21 | GND | Ground | |
22 | GND | Ground | |
23 | GND | Ground | |
24 | GND | Ground | |
25 | n/c | Not connected | |
26 | TERMPWR | Termination Power | |
27 | GND | Ground | |
28 | GND | Ground | |
29 | GND | Ground | |
30 | GND | Ground | |
31 | GND | Ground | |
32 | /ATN | Attention | |
33 | GND | Ground | |
34 | GND | Ground | |
35 | GND | Ground | |
36 | /BSY | Busy | |
37 | GND | Ground | |
38 | /ACK | Acknowledge | |
39 | GND | Ground | |
40 | /RST | Reset | |
41 | GND | Ground | |
42 | /MSG | Message | |
43 | GND | Ground | |
44 | /SEL | Select | |
45 | GND | Ground | |
46 | /C/D | Control/Data | |
47 | GND | Ground | |
48 | /REQ | Request | |
49 | GND | Ground | |
50 | /I/O | Input/Output | |
51 | GND | Ground | |
52 | res | Reserved | |
53 | res | Reserved | |
54 | res | Reserved | |
55 | res | Reserved | |
56 | res | Reserved | |
57 | res | Reserved | |
58 | res | Reserved | |
59 | res | Reserved | |
60 | res | Reserved |
Note: Direction is Device relative Bus (other Devices).
Contributor: | Joakim Ögren |
Source: | SCSI FAQ |
Copyright © The Hardware Book Team 1996-2004.
May be copied and redistributed, partially or in whole, as appropriate.
Document last modified: 2002-01-10